REDUCTION OF LOCAL HEATING IN TANKS OF POWERFUL TRANSFORMERS BY HEAT-REMOVING LOCAL RADIATORS WITH RIBBED
Article_10 PDF (Українська)

Keywords

transformers
heating
finned radiators

How to Cite

Ivankov, V.F., et al. “REDUCTION OF LOCAL HEATING IN TANKS OF POWERFUL TRANSFORMERS BY HEAT-REMOVING LOCAL RADIATORS WITH RIBBED”. Proceedings of the Institute of Electrodynamics of the National Academy of Sciences of Ukraine, no. 58, May 2021, p. 082, doi:10.15407/publishing2021.58.082.

Abstract

The main approaches, the results of numerical modeling, and examples of the practical application of heat-dissipating radiators made of aluminum, with a flat base, and with ribbing to reduce local heating in ferromagnetic covers and walls of transformer tanks, which arise in cases of concentration of magnetic fluxes from multi-ampere taps or magnetic shunts are presented. The case of thermal coupling of a non-magnetic flange of a yoke beam with a flat base of a radiator (copper plate) is considered, which shows the possibility of reducing local heating of the beam using conductive heat transfer between the shelf and the plate and convection heat transfer from their surfaces to cooling oil. References 4, figures 7.

https://doi.org/10.15407/publishing2021.58.082
Article_10 PDF (Українська)

References

Дульнев Г.Н. Теплообмен в радиоэлектронных устройствах. М.-Л.: Госэнергоиздат, 1963, 288 с.

Керн Д., Краус А. Развитые поверхности теплообмена. М.: Энергия, 1977, 464 с.

Лейтес Л.В. Электромагнитные расчеты трансформаторов и реакторов. М.: Энергия, 1981, 392 с.

Іванков В.Ф., Басова А.В., Хімюк І.В. Методи моделювання трансформаторів та реакторів. К.: Наш формат, 2017, 490 с.