Abstract
Results of experimental studies on physical model of aerodynamics and heat exchange in axial ventilating channels of teeth of the core of the stator of a turbogenerator with air cooling are presented. Advantages of curvilinear channels in comparison with direct channels due to reduction of aerodynamic resistance are shown. References 6, figures 5.
References
Joho R., Baumgather J., Hinkel T., Stephan C.-E., Jung Type Tested Air-cooled Generator in the 500 MVA Range. M. CIGRE Session 2000. Pp. 11 – 101.
Alekseev B.A., Mamikonyants L.G., Polyakov F.A., Shakaryan Yu.G. Problems of electrical machines at a session SIGRE. Electricity. 2009. No 3. Pp. 5 – 9.
Titov V.V., Hutoretsky G.M., Zagorolnaja G.A. etc. Turbogenerators. L.: Energy, 1967. 896 p.
Dubrovin Yu.N., Kadi Oglou I.A., Kartashova T. N., Sharov V.I. Development of a system of air-cooling turbogenerators of the TZF series. In book: Collection "Electric power". 2003. No 42. Pp. 44 – 50.
Ryazanov V.G., Z.E. Chekanovskaya. Coefficient of heat transfer in axial channels of the sheet core. Electrical equipment. No 9. 1972. Pp. 17 – 18.
Antonyuk O.V., Gurevich E.I., Kartashova T. N. Modern problems and prospects of development of gas-cooling turbogenerators. Power plants. No 5. 2014. Pp. 41 – 47.