Abstract
The results of the development of a distance determination method to the ground fault of an overhead line in the network with isolated neutral are presented. The proposed method is based on the measurement of mode parameters of the line. To implement the method at the beginning of the line, the phases of this line are connected to ground through the tanks. The results of experimental studies of the line-in-use faults are presented. Analysis of experimental data shows that the use of traditional distance determination methods to the fault is difficult due to the complex electromagnetic environment, which is caused by the influence of a closely located high-voltage line and other equipment that is under high voltage. The use of first harmonics of currents and voltages significantly improves the accuracy of distance determination to the fault location. References 6, figures 2, table.
References
Baran P.M., Kidyba V.P., Snail O.M. Determination of the type and place of damage on the lines with branches. Elektroenergetychni ta elektromehanichni systemy. 2008. No 615. Pp. 8–13.
Kuznetsov A.P. Determination of the place of treatment on the air lines of electric transmission. M: Energoatomizdat, 1989. 94 p.
Sarin L.I., Shalin A.I., Ilinykh M.V., Pichkhadze A.B., Mikhel A.A. Determination of the place of closure to the ground on overhead lines 6-35 kV. IV-Conference-2006-19.pdf/static.pnpbolid.com
Figurnov E.P., Bodrov P.A. Determination of the place of single-phase ground fault in high-voltage power supply lines of automatic blocking of railways. Releinaia zashchita I avtomatika energosistem, 2004. М.: VVTs. 2004. Pp. 88–93.
Pat. 94145 Ukraine, IPC G 01 R 31/08 (2011.01). Method for determining the distance to the place of single-phase closure to the ground or insulation defect in electrical networks with isolated and compensated neutral. O.S. Mironov, M.D. Dyachenko, V.V. Burlaka, S.K. Bublyk. The owner is Priazovsky State Technical University. UA. No. a200908198; Declared. 03.08.2009; Published. 10.02.2010, Bull. No 3.
Pat. 116005 Ukraine, IPC (2017.01) G06F 11/00. Microprocessor system for determining the distance to the place of closure to the ground in an unbranched system with an isolated neutral voltage of 6-35 kV. B.S. Stogniy, M.F. Sopel, O.I., Grebchenko M.V., Stretovych V.M., Maksymchuk V.F., Stasyuk O.I., Pylypenko Yu.V., Tutyk V.L.; Applicant and patent owner small private enterprise Aniger, UA. No u2016 09336; Declared. 08.09.2016; Published. 10.05.2017, Bull. No 9.
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Copyright (c) 2017 B.S. Stognii, M.F. Sopel, M.V. Grebchenko, V.F. Maksymchuk, Yu.V. Pylypenko